Clearcube R-Series Data Center Products User Manual

Browse online or download User Manual for Communication Clearcube R-Series Data Center Products. ClearCube R-Series Data Center Products User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 154
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - User’s Guide

R-Series Data Center Products User’s GuideRev G

Page 2 - Technical Support

x • Introduction R-Series Data Center Products User’s GuideWEEE InformationSee “Appendix E.Waste Electrical and Electronic Equipment Directive (WEEE)

Page 3 - Contents

76 • Chassis and Blade Installation R-Series Data Center Products User’s Guide

Page 4

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 77Chapter 4. Hardware Upgrade and Replacement ProceduresThe

Page 5

78 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s GuideOther components such as the processor or motherboard are

Page 6

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 79DriversYou can obtain drivers for ClearCube blades from th

Page 7

80 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s GuideUpgrading MemoryOnly use ClearCube-supplied or ClearCube-a

Page 8

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 81• You must populate CPU 0 socket first to enable and opera

Page 9 - Introduction

82 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s GuideModel R3080DThe R3080D motherboard supports DDR3 1333 MHz

Page 10 - ClearCube Products

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 83Installing 3 DIMMs1. Pull the tabs on either side of the m

Page 11 - Symbols – English

84 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s GuideReplacing and Upgrading Hard DisksThe following sections d

Page 12

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 85• Small tray (part number G0700056)—contains up to two har

Page 13 - Safety Guidelines

R-Series Data Center Products User’s Guide Introduction • xiWarnung zum medizinischen oder klinischen Einsatz von ClearCube-ProduktenClearCube-Produk

Page 14 - Symboles – Français

86 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s Guide2. Position the blade so the hard disk tray is facing up (

Page 15

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 877. Place the new hard disk in the tray.– Insert hard disks

Page 16 - Guide de sécurité

88 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s GuideR3080D Hard DiskTo replace or upgrade a 2.5-inch hard disk

Page 17

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 894. Attach the new hard disk.a. Carefully place the new har

Page 18 - Symbole – Deutsche

90 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s GuideR3040S FansEach R3040S has two CPU fans:• CPU fan 0, used

Page 19 - Sicherheitsrichtlinien

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 91Figure 49 The Location of CPU Fan 0, CPU Fan 1, Power Hea

Page 20

92 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s GuideEnsure that you do not loosen memory modules, voltage regu

Page 21 - Símbolos – Español

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 939. Insert the replacement fan in the fan bracket.a. Rest—b

Page 22 - Directrices de seguridad

94 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s GuideR3080D FanThe R3080D CPU fan is attached to the CPU heatsi

Page 23

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 95.4. Remove the 4 screws from the bracket and remove the br

Page 24

xii • Introduction R-Series Data Center Products User’s GuideBelow are the graphical symbols that are used on ClearCube Technology, Inc. Products and

Page 25

96 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s GuideAn indicator on the bottom of the fan shows the direction

Page 26 - R-Series PC Blade

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 97Replacing a Front LCD PanelThis section describes how to r

Page 27 - LED Color Description

98 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s Guide• R3040S—Insert a screwdriver in the access hole, shown be

Page 28

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 99shown below. It might help to push up on the lower tab fro

Page 29 - R-Series Chassis

100 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s Guide8. Replace the LCD panel screw, ensuring that the plastic

Page 30 - Figure 5 ClearCube C/Port

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 101• R3040S—CMOS battery is located near the rear edge of th

Page 31 - Fiber Optic Extension System

102 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s Guide3. There is a release tab at the top of the battery holde

Page 32 - C7420 Fiber C/Port

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 1032. Ensure that you are working with the shorter of the tw

Page 33 - Zero Clients and Thin Clients

104 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s Guidea. Hold the green interposer so the text and labels on th

Page 34

R-Series Data Center Products User’s Guide Hardware Upgrade and Replacement Procedures • 105section, “R3040S Interposer Cards” on page 102, to remove

Page 35 - Site Preparation

R-Series Data Center Products User’s Guide Introduction • xiiiSafety Guidelines Before undertaking any troubleshooting or maintenance procedure, read

Page 36

106 • Hardware Upgrade and Replacement Procedures R-Series Data Center Products User’s Guide5. Slowly insert the new fan pack to ensure proper seatin

Page 37

R-Series Data Center Products User’s Guide Troubleshooting • 107Chapter 5. TroubleshootingIf you have any problems with your system, please check the

Page 38 - Cable Requirements

108 • Troubleshooting R-Series Data Center Products User’s GuidePower IssuesNo power to PC blade • Check the power button on the front of the PC blad

Page 39 - Data CenterUser Desktops

R-Series Data Center Products User’s Guide Troubleshooting • 109Fiber Optic Troubleshooting No video and/or digital link present • Check all the C/Po

Page 40

110 • Troubleshooting R-Series Data Center Products User’s Guide

Page 41 - Free IP Address Requirement

R-Series Data Center Products User’s Guide Appendix A. Specifications • 111Appendix A. SpecificationsR-Series BladesTable 1 PC Blade Specifications

Page 42

112 • Appendix A. Specifications R-Series Data Center Products User’s GuideR4300 ChassisF6150–160 Fiber TransceiverBIOS• Phoenix® BIOS • Supports PXE

Page 43 - Installation

R-Series Data Center Products User’s Guide Appendix A. Specifications • 113Fiber Signal Loss• Maximum signal attenuation through all fiber runs, patc

Page 44 - Chassis Installation

114 • Appendix A. Specifications R-Series Data Center Products User’s Guide

Page 45

R-Series Data Center Products User’s Guide Appendix B. Regulatory Compliance • 115Appendix B. Regulatory ComplianceThe products described in this doc

Page 46 - Chassis Rapid Mount Kit

xiv • Introduction R-Series Data Center Products User’s Guide•Live Circuits – Operating personnel and service personnel must not remove protective co

Page 47

116 • Appendix B. Regulatory Compliance R-Series Data Center Products User’s Guide

Page 48 - Power Cords

R-Series Data Center Products User’s Guide Appendix C. Technical Support • 117Appendix C. Technical SupportContact InformationIn the event any proble

Page 49

118 • Appendix C. Technical Support R-Series Data Center Products User’s GuideReturn Merchandise Authorization (RMA)ClearCube’s policy for products u

Page 50 - R4300 Modules

R-Series Data Center Products User’s Guide Appendix C. Technical Support • 119with the Fiber Transceiver. Refer to the Safety Guidelines on page 4 fo

Page 51 - Network Bay

120 • Appendix C. Technical Support R-Series Data Center Products User’s Guide

Page 52

R-Series Data Center Products User’s Guide Appendix D. Warranty • 121Appendix D. Warranty ClearCube WarrantyFor One to Three YearsPURPOSE. This Clea

Page 53 - Table 5 R4300 Status LEDs

122 • Appendix D. Warranty R-Series Data Center Products User’s GuideThe Defective Product must be shipped back to ClearCube within five (5) business

Page 54

R-Series Data Center Products User’s Guide Appendix D. Warranty • 123GOVERNING LAW. These terms and conditions shall be governed by the laws of the

Page 55 - • Off = Standby

124 • Appendix D. Warranty R-Series Data Center Products User’s Guide

Page 56 - Power Modules

R-Series Data Center Products User’s Guide WEEE • 125Appendix E. Waste Electrical and Electronic Equipment Directive (WEEE)WEEE InformationThe produc

Page 57 - Connecting Cables

R-Series Data Center Products User’s Guide Introduction • xvsignification de ces symboles. Les symboles graphiques et leur signification, ci-dessous,

Page 58 - Spare Allocation Examples

126 • WEEE R-Series Data Center Products User’s GuideInformations sur la DEEELes produits décrits dans ce document sont soumis à la directive 2002/96

Page 59

R-Series Data Center Products User’s Guide WEEE • 127Elektro- und Elektronikaltgeräten nach deren Lebensdauer zu reduzieren. Diese Richtli-nie tritt

Page 60

128 • WEEE R-Series Data Center Products User’s GuideLos materiales usados en este producto, si no se descartan apropiadamente, podría tener efectos

Page 62 - CLEARCU BE

Revision GP/N G02007820120810

Page 63

xvi • Introduction R-Series Data Center Products User’s GuideGuide de sécurité Avant de dépanner ou de commencer des opérations de maintenance, veuil

Page 64 - R3040S Cabling

R-Series Data Center Products User’s Guide Introduction • xviirequis. Pour le remplacement des cordons d'alimentation, consulter Annexe C – Supp

Page 65

xviii • Introduction R-Series Data Center Products User’s GuideSymbole – Deutsche Symbole auf den Geräten geben dem Benutzer und dem Wartungspersonal

Page 66 - System Configuration

R-Series Data Center Products User’s Guide Introduction • xixSicherheitsrichtlinien Vor der Durchführung von Fehlerbehebungs- oder Wartungsarbeiten s

Page 67 - R3080D Cabling

Technical SupportPlease refer to our support website for technical updates, additional warranty information and documentation, and software revisions:

Page 68 - Chassis Backpack

xx • Introduction R-Series Data Center Products User’s Guidevon Netzkabeln finden Sie im Anhang C – Technischer Support (Appendix C – Technical Suppo

Page 69

R-Series Data Center Products User’s Guide Introduction • xxiSímbolos – Español Los símbolos se usan en el aparato para comunicar información específ

Page 70

xxii • Introduction R-Series Data Center Products User’s GuideEstos mismos símbolos se usan en este documento cuando es apropiado para indicar situac

Page 71 - RMM (Bottom View)

R-Series Data Center Products User’s Guide Introduction • xxiii• Adaptadores de alimentación – ClearCube o distribuidores de ClearCube proveen de ada

Page 72 - Configuring the RMM

xxiv • Introduction R-Series Data Center Products User’s GuideLos dispositivos marcados cumplen con el código federal FDA 21 CFR 1040 por notificació

Page 73

R-Series Data Center Products User’s Guide ClearCube Architecture and Product Overview • 1Chapter 1. ClearCube Architecture and Product OverviewThe C

Page 74

2 • ClearCube Architecture and Product Overview R-Series Data Center Products User’s GuideR-Series PC Blade The ClearCube PC blade is a dedicated com

Page 75 - Configuring the RMC

R-Series Data Center Products User’s Guide ClearCube Architecture and Product Overview • 3A display area at the front of each blade provides active s

Page 76

4 • ClearCube Architecture and Product Overview R-Series Data Center Products User’s GuideFigure 2 ClearCube R-Series Blade Front Panel Display outs

Page 77

R-Series Data Center Products User’s Guide ClearCube Architecture and Product Overview • 5R-Series ChassisThe ClearCube R-series chassis is a central

Page 78

R-Series Data Center Products User’s Guide Contents • iiiContentsHow to Use this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 79

6 • ClearCube Architecture and Product Overview R-Series Data Center Products User’s GuideFigure 4 R4300 Chassis Rear ViewC/PortThe C/Port, shown in

Page 80

R-Series Data Center Products User’s Guide ClearCube Architecture and Product Overview • 7Multi-Video SolutionThe ClearCube multi-video solution prov

Page 81 - LC Connector on C/Port End)

8 • ClearCube Architecture and Product Overview R-Series Data Center Products User’s GuideFiber TransceiverThe Fiber Transceiver, shown in Figure 7,

Page 82 - PC Blade Installation

R-Series Data Center Products User’s Guide ClearCube Architecture and Product Overview • 9Zero Clients and Thin ClientsClearCube PCoIP® zero clients

Page 83

10 • ClearCube Architecture and Product Overview R-Series Data Center Products User’s Guide

Page 84 - Connecting Ethernet Cables

R-Series Data Center Products User’s Guide Network Planning and Site Preparation • 11Chapter 2. Network Planning and Site PreparationRack and Cabinet

Page 85

12 • Network Planning and Site Preparation R-Series Data Center Products User’s GuideFully enclosed electrical cabinets are the preferred option for

Page 86 - R1350 Monitor Support

R-Series Data Center Products User’s Guide Network Planning and Site Preparation • 13Power and Cooling RequirementsThe ClearCube Support site provide

Page 87 - Changing CMOS Settings

14 • Network Planning and Site Preparation R-Series Data Center Products User’s GuideIf you are putting multiple chassis assemblies on a single power

Page 88

R-Series Data Center Products User’s Guide Network Planning and Site Preparation • 15Each fully loaded chassis requires eight C/Port cables with RJ-4

Page 89

iv • Contents R-Series Data Center Products User’s GuideChapter 3. Chassis and Blade Installation. . . . . . . . . . . . . . . . . . . . . . . . . .

Page 90

16 • Network Planning and Site Preparation R-Series Data Center Products User’s GuideFigure 12 ClearCube Digital Fiber C/Port Architecture Cabling D

Page 91 - Enable RAID in BIOS

R-Series Data Center Products User’s Guide Network Planning and Site Preparation • 17The following figure shows cabling between PCoIP zero clients an

Page 92

18 • Network Planning and Site Preparation R-Series Data Center Products User’s Guide

Page 93

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 19Chapter 3. Chassis and Blade InstallationThe following instructions are

Page 94 - <none>. This is

20 • Chassis and Blade Installation R-Series Data Center Products User’s Guide• Monitors and keyboards – Monitors are normally shipped in their own c

Page 95 - Storage Devices

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 21Begin installing your chassis assemblies at the bottom of the rack or c

Page 96 - MSL Header J7

22 • Chassis and Blade Installation R-Series Data Center Products User’s GuideFigure 15 Side View of Chassis Centered in a Two-Post Rack6. Attach th

Page 97

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 23To install a chassis using the CRM kit, do the following:Figure 16 Rac

Page 98 - Enable Disable

24 • Chassis and Blade Installation R-Series Data Center Products User’s Guide4. Pull the rack bracket forward and insert the front rack ears on the

Page 99 - Flashing the Blade BIOS

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 25The standard 10-amp power cords are acceptable for use with the Fiber T

Page 100

R-Series Data Center Products User’s Guide Contents • vR4300 Chassis Upgrade Kit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 101 - Replacement Procedures

26 • Chassis and Blade Installation R-Series Data Center Products User’s GuideThe R4300 accepts the modules as shown in the positions in Figure 18.Fi

Page 102

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 27The first three characters of a module’s serial number, shown on the ba

Page 103

28 • Chassis and Blade Installation R-Series Data Center Products User’s GuideFigure 21 R4300 Modules The Connect Module (shown on the left in Figur

Page 104 - Upgrading Memory

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 29ADMIN OUT Yellow RJ45 connection that links to the ADMIN IN connection

Page 105

30 • Chassis and Blade Installation R-Series Data Center Products User’s GuideSTATUS Blue • C/Port connection status — Green = good digital link to b

Page 106 - Model R3080D

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 31Table 6 R4300 Remote Management Module FeaturesConnectors Label Colo

Page 107 - Model R1350

32 • Chassis and Blade Installation R-Series Data Center Products User’s GuidePower Modules The R4300 contains two Power Supply Units (PSUs) and a Du

Page 108 - R3040S Hard Disks

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 33The PSUs are factory-installed, field-replaceable units. Each PSU has a

Page 109 - CMOS Battery

34 • Chassis and Blade Installation R-Series Data Center Products User’s GuidePrimary, and RMMs on the chain all serve as Tertiary controllers. A Con

Page 110

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 35blades (configured by daisy-chaining the spare connections). Figure 23

Page 111 - Hard Disk #1Hard Disk #2

vi • Contents R-Series Data Center Products User’s GuideR3040S Hard Disk Tray, Drive Layout, and SATA Headers on Motherboard. . . . . 85Replacing an

Page 112 - R3080D Hard Disk

36 • Chassis and Blade Installation R-Series Data Center Products User’s Guidethan one switch and/or subnet to better protect against network-related

Page 113 - Replacing CPU Fans

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 37We suggest routing the cables down the sides of the rack to the back pa

Page 114 - R3040S Fans

38 • Chassis and Blade Installation R-Series Data Center Products User’s Guidecontrol. One or more RMMs need to be connected to Ethernet to allow aut

Page 115 - Release Tab

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 39Figure 26 Daisy-Chain Examples Spare Daisy Control Chain with Multiple

Page 116

40 • Chassis and Blade Installation R-Series Data Center Products User’s GuideR3040S CablingBecause R3040S blades use two slots in a chassis, the rea

Page 117

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 41blade and client are on the same subnet or, if they are on different su

Page 118 - R3080D Fan

42 • Chassis and Blade Installation R-Series Data Center Products User’s GuideMAC Address Label on R-Series BladesA label on the exterior of each R-s

Page 119

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 43R1350 LabelsThe following figure shows the label on the blade exterior

Page 120 - Heatsink Fan

44 • Chassis and Blade Installation R-Series Data Center Products User’s GuideHow OS Network Connections Are Mapped to NICs on Chassis BackpackAfter

Page 121 - Replacing a Front LCD Panel

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 453. Telnet into the Primary RMM and verify your RMM firmware version. a.

Page 122

R-Series Data Center Products User’s Guide Contents • viiReturn Merchandise Authorization (RMA) . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 123 - Clear of Blade Frame

46 • Chassis and Blade Installation R-Series Data Center Products User’s Guide2. Unzip the update package and read the enclosed Technical Bulletin (a

Page 124 - Holes are Aligned

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 47RMMs can only be installed in R4300 chassis. A BSBP without an RMC inst

Page 125

48 • Chassis and Blade Installation R-Series Data Center Products User’s Guide• Do not use Mixed Mode (connecting a mix of R4300s, BSBPs, and/or DCBP

Page 126 - R3040S Interposer Cards

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 49The following figure shows the list of configuration parameters.Figure

Page 127

50 • Chassis and Blade Installation R-Series Data Center Products User’s GuideRMMGateway RMM Gateway Ignored if IP Mode = DHCP 192.168.1.1 RMMLocat

Page 128

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 51Configuring the RMC The following steps outline the process required to

Page 129 - Replacing the R4300 Fan Pack

52 • Chassis and Blade Installation R-Series Data Center Products User’s Guide• Configure the Blade Switching BackPack for Various Modes: Configurati

Page 130

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 53each RMC with a different IP address. This allows you to log in to each

Page 131 - Chapter 5. Troubleshooting

54 • Chassis and Blade Installation R-Series Data Center Products User’s GuideThe result should be:>1new ip:4. Type in the desired new IP address.

Page 132 - Video Issues

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 55Connect the CONTROL IN port to your regular network using a standard ne

Page 133 - Fiber Optic Troubleshooting

viii • Contents R-Series Data Center Products User’s Guide

Page 134

56 • Chassis and Blade Installation R-Series Data Center Products User’s Guide6. Remove the 2 Phillips screws retaining the BackPack. 7. Pull the Bac

Page 135 - Appendix A. Specifications

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 57Fiber Transceiver and Cable RequirementsSee ClearCube F6150 Fiber Trans

Page 136 - F6150–160 Fiber Transceiver

58 • Chassis and Blade Installation R-Series Data Center Products User’s GuideThe fiber optic cables from the output of the Transceiver can be home r

Page 137 - Environmental

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 59To install a blade, do the following:1. Lower the front bezel on the ch

Page 138

60 • Chassis and Blade Installation R-Series Data Center Products User’s GuideWhen a blade is inserted into a chassis, it takes approximately 30 seco

Page 139

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 61To connect C/Ports to a dual-slot blade, use only the even-numbered C/P

Page 140

62 • Chassis and Blade Installation R-Series Data Center Products User’s GuideWhen connecting to an R3040S, use the even-numbered USB ports on the ba

Page 141 - Appendix C. Technical Support

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 63two or more DVI-I displays to your PCoIP client. Perform the following

Page 142

64 • Chassis and Blade Installation R-Series Data Center Products User’s GuideFrom the BIOS setup utility you can configure boot sequence, hard disk

Page 143

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 65Figure 33 Model R1350 MSL and CMOS Jumper Locations and SettingsCleari

Page 144

R-Series Data Center Products User’s Guide Introduction • ixIntroductionHow to Use this GuideThank you for purchasing your quality ClearCube products

Page 145 - ClearCube Warranty

66 • Chassis and Blade Installation R-Series Data Center Products User’s GuidePerform the following steps to clear all CMOS settings.1. Power down th

Page 146 - ISCLAIMER

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 67ClearCube blade image and from the ClearCube Support Web site before yo

Page 147 - WEEE Directive

68 • Chassis and Blade Installation R-Series Data Center Products User’s Guide10. Press F10 to save your changes and exit Setup.11. Select OK and the

Page 148

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 693. From the Name field, type a name for the RAID volume you are creatin

Page 149 - Directive (WEEE)

70 • Chassis and Blade Installation R-Series Data Center Products User’s GuideFrom the Support site, click PC Blades > R3040S > Drivers and the

Page 150 - Informationen über WEEE

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 717. Setup displays a screen requesting that you specify the SCSI adapter

Page 151 - La información de REEE

72 • Chassis and Blade Installation R-Series Data Center Products User’s GuideMSL is disabled by default. To enable MSL, you must set a jumper on the

Page 152

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 73– R1350 Using a C/PortMSL header JP6 is located to the left of the DIMM

Page 153

74 • Chassis and Blade Installation R-Series Data Center Products User’s Guide– R3040SMSL header JP6 is located near the top edge of the motherboard,

Page 154 - 20120810

R-Series Data Center Products User’s Guide Chassis and Blade Installation • 75Flashing the Blade BIOSYou can flash (install or re-install) the BIOS f

Related models: R Series

Comments to this Manuals